Atex and ACD vacuum cleaners
MINIBULL H ACD INERT Industrial Vacuum for Inerting Combustible Dust
Modelli disponibili
ACD-classified industrial vacuum for suctioning combustible dust in non-Atex classified areas. Two powerful single-phase motors that can be operated independently, complete grounding, and a stainless steel container with inerting liquid bath designed for safe suctioning of Type IIIC conductive dust. Antistatic accessories and interchangeable container for IIIB dust available as options.
- ACD classified for combustible dust extraction in non-Atex classified areas
- Container with inerting liquid bath that prevents the formation of explosive atmospheres inside the extractor
- Ideal for safe extraction of conductive metal dust
- Vacuum gauge for performance monitoring
Potenza
2,6 kW
Applicazione
Combustible dusts
Tipo di raccolta
Liquid bath inerting system
Technical data
Engine
| Tipologie | By-pass |
| Potenza | 2,6 kW - 3,5 HP |
| Frequenza | 50/60 Hz |
| Voltaggio | 230 V |
| Vuoto in continuo | 250 mBar |
| Massima portata d'aria | 380 m3/h |
| Insulation class | 54 | F IP |
| Livello di rumorosità | 72 dB(A) |
Macchina
| Bocca aspirante | 50 Ø mm |
| Sistema di raccolta | Container with inerting liquid |
| Capacity | 45 Lt |
| Sistema di scarico liquidi | Discharge valve |
| Dimensioni | 550 x 620 mm |
| Altezza | 1400 mm |
| Peso | 50 Kg |
| Separazione solido | Basket grid |
| Separazione liquidi | 150μm liquid filter |
| Safety valve | Hydrogen Vent |
Filtrazione
| Tipologia filtro primario | Cartridge |
| Superficie filtrante | 35000 cm2 |
| Classe filtrazione EN 60335-2-69 | H13 |
| Media | Antistatic polyester |
| Filtro aggiuntivo | Spark trap |
Highlights
Dotazioni
Options
STRUCTURE AND OPTIONS